Chapter 6 - EN 50131 Compliance
Compliance Statement
Hereby,RISCOGroupdeclaresthattheAgilityseriesofcentralunitsandaccessoriesare
designedtocomplywith:
EN501311,EN501313Grade2
EN501305Enviro nmentalclassII
EN501316TypeA
UK:PD6662:2004,ACPODD243:2004(Police)
Possible logical keys calculations:
Logicalcodesarecodestypedinthewirelesskeypadtoallowlevel2(users)and
level3(installer)access
Allcodelengthsare4digitslong
09canbeusedforeachdigit
Therearenodisallowedcodes,allcodesfrom0001to9999areacceptable
Invalidcodescannotbecrea ted sinceafter4digi tshavebeentypedʺEnterʺis
automatic.Codesrejectionoccursonly whentr y ing tocreateacodethatdoesnot
exist.
Possible physical keys calculations:
Physicalkeysarei m plement ed intheWirelessRemoteControls.
Itisassumedonlyausercanhaveremotecontrols,sohavingaphysicalkeyis
consideredasaccesslevel2
Eachremotecontrolhasanidentificationcodeof24bit,sothenumberofoptions is
2^24
ForaremotecontroltooperatewiththeAgility,aʺwr ite ʺprocess mustbemade
afterwhichthekeypadisregisteredwiththepanel.
AvalidremotecontrolisoneʺLearnedʺbythepanelandallowsArm/Disarm
AnonvalidremotecontrolisonenotʺLearnedʺbythepanelanddoesnotallow
Arm/Disarm