Chapter 2-2
Robomow RL555, RL855, RL2000
P If setting of Base Station is external (outside lawn)
) Peg the beginning of the wire to the ground, at a distance of
1m (3.3 feet).
) Pull out 40 cm (16 inches) of wire and leave it loose at the
Base Station location. This allows for later adjustments of
the Base Station.
) Start laying the wire in a counter-clockwise direction at the
external area of the Base Station.
Continue laying the wire for at least 30 cm (12 inch) away from
the lawn.
Set a Narrow Pass, 20 cm (8 inches) wide, in the direction of
the lawn, until the wire is 30 cm (12 inches) inside the lawn.
) Continue to pull the Perimeter Wire out of its covering,
laying it loosely as you walk along the lawn edge.
































20 cm
(8’’)
30 cm
(12’’)
1
Starting point – 1 m (3.3 ft)
from lawn’s edge
2
Leave 40 cm (16’’) of
coil at starting point,
for later adjustments.
3
Continue for at
least 30 cm (12’’)
away from lawn.
4
Set a narrow pass of
20 cm (8’’) towards
lawn. Continue until
wire is 30 cm (12’’)
inside lawn.
5
Continue laying the
wire, using RoboRuler
along edges.