Robustel GoRugged M1000 User Guide
RT_UG_M1000 Standard_v.2.0.0 20.12.2013 38 / 83
Confidential
parameters when triggered.
Null: Do nothing.
Alarm Off Action
Digital Output acts when alarm recovered.
Selected from OFF, ON, Pulse, Null.
OFF: Open when triggered.
ON: Short contact when triggered.
Pulse: Generates a square wave as specified in the pulse mode
parameters when triggered.
Null: Do nothing.
Null
Status When Power
On
Specify the Digital Output status when power on.
Selected from OFF, ON.
OFF: Open.
ON: Short contact.
Null
Keep On
Available when digital output Alarm On Action/Alarm Off Action
status is ON, input the Digital Output keep on status time.
Input from 0 to 255 seconds. (0=keep on until the next action)
0
Triggering Alarm
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable Alarm On Action by SMS. (70 ASIC
II char max)
Null
Recovering Alarm
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable Alarm Off Action by SMS. (70 ASIC
II char max)
Null
Phone Group
The alarm SMS will send to specified phone group.
Each phone group include up to 10 phone numbers.
Null
Low
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The low level widths are specified here.
Input from 1 to 30000 ms.
1
High
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The high level widths are specified here.
Input from 1 to 30000 ms.
1
Output
Available when enable Pulse in Alarm On Action/Alarm Off Action.
The number of pulses, input from 0 to 30000. (0 for continuous pulse
output)
1
Delay
Available when enable Pulse in Alarm On Action/Alarm Off Action.
The first pulse will be generated after a Delay.
Input from 0 to 30000ms. (0=generate pulse without delay)
0

Table of Contents

Other manuals for Robustel GoRugged M1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robustel GoRugged M1000 and is the answer not in the manual?

Robustel GoRugged M1000 Specifications

General IconGeneral
BrandRobustel
ModelGoRugged M1000
CategoryModem
LanguageEnglish

Related product manuals