EasyManuals Logo

Robustel GoRugged M1000 User Manual

Default Icon
85 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #74 background imageLoading...
Page #74 background image
Robustel GoRugged M1000 User Guide
RT_UG_M1000 Standard_v.2.0.0 20.12.2013 73 / 83
Confidential
0 - don't ignore AT^SMSO
1 - ignoreAT^SMSO
value: 0 - 60s (power on delay turn on
module)
1020
Set Singal Update
Frequency
cmd,value
value: 5 - 1200s
1021
Set Init String
cmd,index,content
index: 0 - 3(0 - M1000 will auto generate a
index when the init string array isn't full)
content: max 40 bytes
1022
Set Phone Number
cmd,index,number,flag
index: 0 - 10(0 - M1000 will auto generate a
index when the phone book isn't full)
number(max 20 bytes)
flag: xxxxx (binary format: 00000 - 11111)
flag.0:
0 - disable call reboot
1 - enable call reboot
flag.1:
0 - disable sms reboot
1 - enable sms reboot
flag.2:
0 - disable sms in
1 - enable sms in
flag.3:
0 - disable sms out
1 - enable sms out
flag.4:
0 - disable sms control
1 - enable sms control
1023
Set Phone Group
cmd,index,flag
index: 1 - 10(phone group index)
flag: xxxxxxxxxx (binary format:
0000000000 - 1111111111)
flag.0 ~ flag.9: (phone number index)
0 - exclude in this phone group
1 - include in this phone group
1024
Set Modbus
Parameters
cmd,flag1,id,address1,address2,flag2,
address3,address4,address5,address
6,address7
flag1:
0 - enable modbus
1 - disable modbus
*id - slave address
*address1 - coil address
*address2 - register address
*flag2:
0 - enable PLC send SMS
1 - disable PLC send SMS

Table of Contents

Other manuals for Robustel GoRugged M1000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Robustel GoRugged M1000 and is the answer not in the manual?

Robustel GoRugged M1000 Specifications

General IconGeneral
BrandRobustel
ModelGoRugged M1000
CategoryModem
LanguageEnglish

Related product manuals