198 Rockwell Automation Publication 2198-UM005C-EN-P - February 2022
Appendix C Motor Control Feature Support
Frequency Control Methods The Kinetix 5300 servo drives support three open-loop frequency control
methods. These are the choices:
Basic Volts/Hertz - This method is used in single asynchronous-motor
applications
•Basic Volts/Hertz - Fan Pump - This method is similar to Basic Volts/
Hertz, but is specifically tailored for fan/pump applications
Sensorless Vector with Slip Compensation - This method is used for
most constant torque applications. Provides excellent starting,
acceleration, and running torque
To configure your induction motor in the Logix Designer application, refer to
Configure Induction-motor Closed-loop Control Axis Properties
on page 128.
Open-loop frequency control is suitable in applications such as conveyors,
pumps, and fans. Features include the following:
Start Boost and Run Boost
Electronic motor thermal-overload protection per Class 10 requirements
Two skip frequencies, in which the drive does not operate
All three-phase induction motors, suitable for variable speed drive (VFD)
operation, are supported
Table 92 - Motor Specifications
Attribute Value
Output frequency, max 590 Hz
Pole pairs, max 50
Motor cable length, max 30 m (98.4 ft)