3-46 Programming and Parameters
UTILITY (File E)
Alarms
259 [Alarm Config 1]
Enables/disables alarm conditions that will initiate an active drive alarm.
File E
Group
No.
Parameter Name and Description
See page 3-2 for symbol descriptions
Values
Related
111111x11101000x
10 01234567891112131415
1 =Enabled
0 =Disabled
x =Reserved
Bit #
Factory Default Bit Values
Prechrg Actv
UnderVoltage
Power Loss
Str At PwrUp
Anlg in Loss
IntDBRes OH
Drv OL Lvl 1
Drv OL Lvl 2
Decel Inhibt
Waking
(2)
Motor Therm
(1)
In PhaseLoss
(2)
Load Loss
(2)
Ground Warn
(2)
Nibble 1Nibble 2Nibble 3Nibble 4
(1)
Enhanced firmware 1.001 & later.
(2)
Enhanced firmware 2.001 & later.