If
no Variation Select messages are specified, Variation 0 and Page 0 will be used. Pressing 0
(General Cancel) at any time will exit the procedure.
Selecting a PG key higher than
128
"Low F (Pedal)" will disable sending any PG and Variation
messages for a MIDI coupler. Also switching on the coupler will not send any messages. Selecting
values higher than 128 for the Variation Number and Page Number will disable sending these
Variation messages.
SAVING A COMBINATION MEMORY
The contents of all combination memory may be saved into a MIDI sequencer and later reloaded
into the organ.
To
save the entire memory:
1.
The Master Clock on the sequencer must be on.
2.
Start the sequencer, and wait for it
to
begin recording.
3.
While holding SET, press or M2 to begin the transmission
of
all memory information.
4. Stop the sequencer after all pistons have been saved (about 5 seconds).
To
restore a memory from the sequencer:
1.
Start the sequencer playback. After a few seconds the memory will be restored.