16 Alarms and faults
PROBLEM ALARM SIGNAL POSSIBLE CAUSE CORRECTIVE ACTION
The barrier does
not open or close.
POWER LED off
No power. Check power cable.
POWER LED off
Fuses blown. Replace fuse.
Always disconnect from mains power before remov-
MRKERHVIƼXXMRKJYWIW
)86(
Fuse F1 blown or damaged.
This message is not visible if
controller is in battery power
mode.
Replace fuse.
Always disconnect from mains power before remov-
MRKERHVIƼXXMRKJYWIW
2)6W
Input mains power voltage
fault.
Controller initialisation failed.
Disconnect from mains power, wait 10 seconds then
reconnect to the mains and switch on.
We recommend replacing the control unit if the prob-
lem persists.
3U2W
Overcurrent detected in in-
verter.
Press the TEST button twice or perform 3 command
requests in succession.
6(&2
Incorrect connection between
SEC1 and SEC2 of the trans-
former.
Swap the connection between SEC1 and SEC2.
G$W$
Travel data acquisition error. Check that the spring is balanced correctly with the
barrier unlocked.
Press TEST and check if any safety devices are in
alarm state.
Repeat acquisition procedure.
Calibration procedure failed
(3+$6).
Allow the indicated calibration times to elapse during
self-acquisition.
Before re-closing the release lock cover, ensure that
SRXLIHMWTPE][MPPƽEWL3+$6. Repeat acquisition
procedure.
Automation system position
WIPIGXMSRQSHMƼGEXMSRQIWWE-
ge with parameter .
DX
SX
1SXSVWJSVFEVVMIVWEVIJEGXSV]GSRƼKYVIHJSVVMKLX
hand opening barriers  (position of barrier re-
lative to passage seen from inspection hatch side).
If the position is changed and message 'DWD is di-
WTPE]IH
Move the boom 45° degree.
Adjust the spring position correctly for the requi-
red opening direction.
Press and hold PROG until '$7$ disappears and
$33 appears on the display.
Repeat acquisition procedure.
Motor not connected. Check the motor cable.
EU($
BreakAway system alarm. Check the setting of par. .
Check the correct ACS/BA/60 system connection
to the control unit.
Re-engage the boom.
Consider replacing the boom if it is damaged.
)\EQTPI
HH
HH
'SRƼKYVEXMSRTEVEQIXIV
error.
7IXGSRƼKYVEXMSRZEPYIGSVVIGXP]ERHWEZI
...Continued

Other manuals for Roger Technology CTRL

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Roger Technology CTRL and is the answer not in the manual?

Roger Technology CTRL Specifications

General IconGeneral
BrandRoger Technology
ModelCTRL
CategoryControl Unit
LanguageEnglish

Related product manuals