Note: Setting S=0 and KL=00 will set unlimited open time thus will disable indication of a Door
Ajar alarm.
[73][S][KL] – Programming Duress Timer, S=0..1, KL=00..99, default: S=1 KL=03
This timer defines duration time for Duress Alarm. When S=0 and KL=00 then the alarm will be
triggered indefinitely until the reader’s arming mode is switched.. Program S=0 for seconds or S=1
for minutes. Setting S=1 and KL=00 is forbidden.
[74][S][KL] – Programming LED STATUS Timer, S=0..1, KL=00..99, default: S=0 KL=00
This timer defines time for which LED STATUS will be on after arming mode is changed. Program
S=0 for seconds or S=1 for minutes. Setting S=0 and KL=00 or S=1 and KL=00 is forbidden.
Note: This timer has been used only when LED STATUS Masking function is activated.
[75][L] – Programming keypad backlight level, L=0..5, default: L=3
The L digit defines keypad backlight level. Program: L=0 for 0% (backlight is off), L=1 for 20%,
L=2 for 40%, L=3 for 60%, L=4 for 80% or L=5 for 100% (maximum backlight).
[76][L] – Programming buzzer loudness level, L=0..5, default: L=3
The L digit defines buzzer loudness level. Program: L=0 for 0% (sound is off), L=1 for 20%, L=2
for 40%, L=3 for 60%, L=4 for 80% or L=5 for 100% (maximum sound).
[77][L] – Programming LED STATUS Masking function, L=0..1, default: L=0
When L=0 LED STATUS continuously indicates current arming mode of the unit. When L=1 LED
STATUS is normally in neutral mode (sequentially switches from green to red and vice verso
however whenever arming mode is changed or unit is restarted it lights up for time defined by LED
STATUS timer and then switches to neutral mode again.
Note: Use this function in case you want to keep secret current arming mode of the unit.
[78][L] – Programming Real Time Clock Control option, L=0..1, default: L=0
When L=0 reader continues normal operation even when reader’s clock is unset or lost. When L=1
reader stops its normal operation however user can use keypad to set clock and restore normal
reader operation.
Note: When option is active and clock is unset or lost, all LED-s are pulsing and reader stops its
normal operation. In order to restore normal operation set the clock either manually or from PC.
[79][D] – Programming Duress function, D=0..1, default: D=0
When D=0 reader will not either recognize nor signal entering of PIN under duress. When D=1
entering a valid PIN code with last digit modified by +/-1 will be treated as under duress and will
cause signalling on output line (when programmed).
[80] [SSWW] – Programming Winter/Summer time change
SS: Day in March when time is changed from Winter to Summer (clock is moved from 2:00 to
3:00). Setting SS=00 deactivates automatic time change while programming SS=99 makes device
will change Winter/Summer time on last Sunday of March.
WW: Day in October when time is changed from Summer to Winter (clock is moved from 3:00 to
2:00). Setting WW=00 deactivates automatic time change while programming WW=99 makes
device will change time on last Sunday of October.
[81][ PIN][#][Card] – Programming new MASTER user
Programs PIN and card for MASTER user. Optionally, program [81][PIN][#][#] to omit card
programming or [81][Card] to omit PIN programming.
[82][PIN][#][Card] – Programming new INSTALLER PIN and/or card