PRTxxEM series readers Operating Manual.doc 2018-08-21
Timer however whenever reader changes its arming mode
this output is immediately cleared. When corresponding timer
is set to 00s output it activated for unlimited time - till
moment when reader changes its arming mode again.
Output, line is triggered in the moment when Intruder
Alarm is raised. Output remains active for time defined by
Intruder Timer however whenever reader changes its
arming mode this output is immediately cleared. When
corresponding timer is set to 00s output it activated for
unlimited time - till moment when reader changes its arming
mode again.
Output, line is triggered in the moment when Tamper Alarm
or Intruder Alarm is raised. Output remain active for a
time defined by General Alarm Timer however whenever
reader changes its arming mode this output is immediately
cleared. When corresponding timer is set to 00s output it
activated for unlimited time - till moment when reader
changes its arming mode again.
Output, line is triggered in the moment when access is
granted and remains active for the entire time when door
lock is released (same as Door Unlock Time).
Output, line is active for the entire time when reader waits
for a door to become closed (same as Door Open Timeout).
Output, line is triggered in the moment when Duress Alarm
is raised. Output remains active for time defined by Duress
Alarm Timer however whenever reader changes its arming
mode this output is immediately cleared.
Output, line is triggered in the moment when reader changes
its arming mode and remains active as long as LED STATUS
presents actual arming mode.
Output, same as [41]: Door Lock but inverted (normally
this output is on, when triggered it goes off).
9. U S E R P R O G R A M M I N G M O D E
User Programming mode enables management of users registered in the reader (add and delete
cards and PIN-s). Alternatively users can be managed with RARC software after connection of
reader to computer.
To enter this mode, read one time your MASTER card or enter your MASTER PIN. When in User
Programming mode, LED OPEN (green) is on and LED STATUS lights in red. In User
Programming mode you have set of programming commands. When you begin to enter any of
them, LED SYSTEM starts flashing and it keeps flashing until this command has been correctly
completed. If reader receives no valid input (entries) for more than 10 sec (between the successive
steps of the command sequence), it automatically ends the command sequence, however it still
remains in User Programming mode so that you may return to any user programming command
or you may press [#] to exit this programming mode. Alternatively you may wait ~1 min for the
reader to leave User Programming mode automatically.
Note: Each user ID index consists always of three digits to form ID numbers ranging 000–119. In
case you assign a new user the ID that is already occupied by some other user, this will remove
the older one from the memory.