Test Report R&S CMU
1100.4903.82 1.26 E-5
Item
No.
Description
Measure-
ment
to section
Min. Actual Max.
Measurement
uncertainty
Unit
TX In-band spurious
R&S CMU setting = 468.1 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 489.3 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 496.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 925.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 960.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1805.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1880.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 869.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 894.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1930.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1990.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1920.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 1980.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc
TX In-band spurious
R&S CMU setting = 2110.5 MHz
search freq. ± (5 to 500) kHz from
carrier
–40 dBc