IV. SYSTEM SETTINGS
SYSTEM SETUP
1. While holding down the EXIT button, turn the power on.
2. Use the following buttons to select a parameter, and use the VALUE knob to specify the value.
3. Press the VALUE knob to save the setting.
4. Power Cycle the SE-02.
BUTTON PARAMETER VALUE EXPLANATION
[1] MIDI CHANNEL OFF, 1-16
OMn
Specifies the MIDI channel: 1-16
OMn: All messages are received (transmitted on CH1)
[2] CHAIN OFF, ON Increase the polyphony by using a MIDI cable to
connect two or more SE-02 units and turning chain
mode on.
[3] AUTO OFF OFF
30, 240
MINUTES
The power does not turn off automatically
The power turns off when the set time elapses.
Auto OFF does not occur while USB connected.
[4] SAVER TIME OFF, 1, 3, 10
MINUTES
Specifies the time until the LED DEMO is shown
[5] CC OUT OFF, USB,
MIDI, BOTH
USB & MIDI
Selects the output destination for control changes.
OFF: No output USB: Output only to USB
MID: Output only to MIDI U-M: USB and MIDI
[6] PC OUT OFF, USb,
Mid, U-M
Output destination for program changes. OFF: not
output, USB: output only to USB, Mid: output only to
MIDI, U-M: output to USB and MIDI (V1.10+)
[7] Sync P-S, Int,
Nid, Usb,
trg
Specifies the clock to which the song synchronizes.
p-S: tempo of the pattern/song, Int: internal clock,
Mid: MIDI, Usb: USB MIDI, trg: trigger signals input to
the TRIGGER IN jack (V1.10+)
[8] Midi KEY Trigger OFF, ON If this is On, key trigger can be controlled from an
external MIDI device. (V1.10+)
[9] Midi Thru OFF, ON If this is On, MIDI messages that are input to the MIDI
IN connector are transmitted without change to the
MIDI OUT connector. (V1.10+)
[16] VERSION – Indicates the current version