Controller functions
Page 38 RES-403 Version 1
Error messages up to September 2005
Action if machine
already operating,
HS-band not chang.
Fault area
Fault area
Fault areas

Fault areas

(loose contact)
Check power supply
Run RESET
Replace controller
Fault areas

---
---
---
---
Action
if machine started
for first time
Fault area
Fault area
Fault area
Fault areas

(loose contact)
Check power supply
Run RESET
Replace controller
Run AUTOCAL
Run AUTOCAL
Fault area
,
check configuration
Fault area
,
check configuration
Fault areas
,
check configuration
Cause
I
R
signal missing
U
R
signal missing
U
R
and I
R
signals missing
Temperature step
Frequency fluctuation,
inadmissible line frequency
Internal fault
Internal fault,
controller defective
U
R
and/or I
R
signal
incorrect
Data error
I
R
signal incorrect,
calibration not possible
U
R
signal incorrect,
calibration not possible
U
R
and I
R
signals incorrect,
calibration not possible
STATUS
of alarm relay
(factory set.)
Closed
Open,
does not close
until "START"
signal
(voltage value
at analog
output then
no longer
changes)
ALARM
LED
Lit
Continuously
Blinks
fast
(4Hz)
Blinks
slowly
(1Hz)
Temp.
500°C
[°C]
33
66
100
133
166
200
233
266
500
300
500
333
500
365
500
400
500
Temp.
300°C
[°C]
20
40
60
80
100
120
140
160
300
180
300
200
300
220
300
240
300
Act. value
output ;
Voltage [V]
0.66
1.33
2.00
2.66
3.33
4.00
4.66
5.33
10
6.00
10
6.66
10
7.33
10
8.00
10
Error
code
1
2
3
4
5
6
7
8
9
10
11
12