Controller functions
Page 24 UPT-606
9.4.1 "Compact" protocol with 4-Bit
error code
The 16-bit input data from the PROFIBUS master to
the UPT-606 contains the set point and the control
functions and has the following structure:
The 16-bit output data from the UPT-606 to the PRO-
FIBUS master contains the actual value or the error
code and the status information and has the following
structure:
9.4.2 "Compact" protocol with 10-Bit
error code
The 10-Bit error codes are available on all
controllers as of software revision 100 and
supplied with GSD Version v2.0. These error codes
must be activated in the parameter data
( section 9.7.9 "Error code format" on page 32).
The 16-bit input data from the PROFIBUS master to
the UPT-606 contains the set point and the control
functions and has the following structure:
The 16-bit output data from the UPT-606 to the PRO-
FIBUS master contains the actual value or the error
code and the status information and has the following
structure:
Control function Spare Set point / AC temperature
Name: RS ST AC MP 0 0 0
Bit no.:1514131211109876543210
Error code if AL = 1
Status information Actual value (compact) if AL = 0
Name:AAAGALTETORAVZ A3A2A1A0
Bit no.:1514131211109876543210
!
Control function Spare Set point / AC temperature
Name: RS ST AC MP 0 0 0
Bit no.:1514131211109876543210
Error code if AL = 1
Status information Actual value (compact) if AL = 0
Name: AA AG AL TE TO RA VZ/A9 A8 A7 A6 A5 A4 A3 A2 A1 A0
Bit no.:151413121110 9 876543210