Controller functions
UPT-606 Page 25
9.4.3 "Extended" protocol with 4-Bit
error code
The extended protocol transfers 2x16bits. The 2x16-
bit input data contains the set point in word and the
control functions in word :
The 2x16-bit output data contains the actual value in
word and the error code and status information in
word :
9.4.4 "Extended" protocol with 10-Bit
error code
The 10-Bit error codes are available on all
controllers as of software revision 100 and
supplied with GSD Version v2.0. These error codes
must be activated in the parameter data
( section 9.7.9 "Error code format" on page 32).
The extended protocol transfers 2x16bits. The 2x16-
bit input data contains the set point in word and the
control functions in word :
Spare Set point / AC temperature
Name:0000000
Bit no.:1514131211109876543210
Spare Control function
Name:000000000000MPRSSTAC
Bit no.:1514131211109876543210
Actual value (signed)
Name: VZ
Bit no.:1514131211109876543210
Spare Error code Spare Status information
Name:0 0 0 0A3A2A1A00 0AAAGALTETORA
Bit no.:1514131211109876543210
Spare Set point / AC temperature
Name:0000000
Bit no.:1514131211109876543210
Spare Control function
Name:000000000000MPRSSTAC
Bit no.:1514131211109876543210