EasyManua.ls Logo

Rosslare AYC-FG4 Series - Normal User; Secure User; Master User; Modes of Operation

Rosslare AYC-FG4 Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
C o ntro lle r Func tio na lity
AYC-Fx4 a nd AYC-G x4 fa mily ma nua l Pa g e 28
6.1.1. Normal User
A No rm a l Use r o nly ha s a Prim a ry C o d e a nd is o nly g ra nte d
a c c e ss w he n the AYC -Fx4/ AYC -G x4 is in No rm a l o r Byp a ss Mo d e .
6.1.2. Secure User
A Se c ure Use r must ha ve a Prim a ry a nd Se c o nd a ry C o d e
p ro g ra mme d ; the two c o d e s must no t b e the sa me . The Se c ure
Use r c a n g a in a c c e ss whe n the AYC -Fx4/ AYC -G x4 is in a ny o f its
thre e m o d e s o f o p e ra tio n. In No rma l Mo d e the Se c ure Use r m ust
use the ir Prima ry C o d e to g a in e ntry. In Se c ure Mo d e the Se c ure
Use r m ust p re se nt b o th the ir Prima ry a nd Se c o nd a ry C o d e s in
o rd e r to g a in e ntry.
6.1.3. Master User
A Ma ste r Use r m ust ha ve b o th Prima ry a nd Se c o nd a ry C o d e s
p ro g ra mme d with the sa m e c o d e . The Ma ste r Use r c a n g a in
a c c e ss d uring a ny m o d e o f o p e ra tio n b y p re se nting the ir PIN
c o d e a nd / o r Pro ximity c a rd o nc e to the c o ntro lle r. (The Ma ste r
Use r is c o nve nie nt b ut is le ss se c ure tha n a Se c ure Use r.)
6.2 Modes of Operation
The AYC -Fx4/ AYC -G x4 ha s thre e m o d e s o f o p e ra tio n:
6.2.1. Normal Mode
MODE LED is green
No rm a l Mo d e is the d e fa ult mo d e . In No rm a l m o d e the d o o r is
lo c ke d until a Prima ry C o d e is p re se nte d to the c o ntro lle r. Sp e c ia l
c o d e s suc h a s Loc k Strike C o d e a nd Auxilia ry C o d e a re a c tive in
No rma l mo d e . (Se e p a g e s 34-35 fo r m o re info rm a tio n)
Mode/Transmit
Door/Program
Green

Table of Contents

Related product manuals