C o ntro lle r Func tio na lity
AYC-Fx4 a nd AYC-G x4 fa mily ma nua l Pa g e 38
3) C o nstruc t a c o d e using instruc tio ns he re a fte r.
First Dig it
Fo r fa il se c ure o p e ra tio n, the first dig it is se t to 0.
Fo r fa ilsafe o p e ra tio n, the first d ig it is se t to 1.
Se c o nd Dig it
Sire n Time in m inute s (1-9, 0-d isa b le d )
Third a nd Fo urth Dig its
Ente r the num b e r o f se c o nd s (fro m 1 to 99) tha t
yo u wa nt the Lo c k Strike to b e re le a se d .
Fo r e xa mple , 0312 me a ns Fa il Se c ure O p e ra tio n, a 3-m inute Sire n,
a nd a 12-se c o nd Lo c k Strike re le a se time .
4) Syste m re turns to its no rm a l m o d e .
• Yo u will he a r thre e b e e p s.
• The Do o r LED will turn o ff.
• The Mo d e LED will turn g re e n.
• De fa ult va lue is 0004 whic h c o rre sp o nd s to Fa il Se c ure
o p e ra tio n, no sire n, a nd 4-se c o nd s Lo c k Strike re le a se tim e .
6.9.10. Defining the Auxiliary Input and Output
The d e fa ult a uxilia ry se tting is 2004.
1) Ente r the Pro g ra mming
Mo d e .
2) Pre ss 6 to e nte r Me nu 6.
• The Mo d e LED will fla sh
g re e n
Door/Program
Door/Program