C o ntro lle r Func tio na lity
AYC-Fx4 a nd AYC-G x4 fa mily ma nua l Pa g e 53
6.9.18. Pin Code Length / Factory Default Settings
Wa rning :
Yo u must b e ve ry c a re ful b e fo re using this c o mma nd !
C ha ng ing the p in c o d e le ng th w ill a lso e ra se the e ntire
me m o ry c o nte nts, inc lud ing a ll use r a nd spe c ia l c o d e s, a nd
re turn a ll c o d e s to the ir fa c to ry-d e fa ult se tting s
1) Ente r the Pro g ra mming
Mo d e .
2) Se le c t the d e sire d p in c o d e le ng th a s fo llo ws:
a . 00 Re turns to fa c to ry d e fa ults a nd se ts a 4 d ig it c o d e .
b . 05 - Re turns to fa c to ry d e fa ults a nd se ts a 5 d ig it c o d e .
c . 06 - Re turns to fa c to ry d e fa ults a nd se ts a 6 d ig it c o d e .
d . 08 - Re turns to fa c to ry d e fa ults a nd se ts a 4-8 d ig it c o d e .
No te :
Whe n c ho o sing the 4-8 o p tio n, p le a se no te tha t yo u sho uld
e ithe r e nte r ze ro s b e fo re the c o d e , o r p re ss po und a t the e nd
(fo r e xa mple if yo ur c o d e is 12345, e nte r e ithe r 00012 34 5 o r
12345#).
Bo th the Mo d e a nd Do o r
LEDs will fla sh re d .
3) Ente r yo ur 4-8 d ig its Pro g ra m m ing
C o d e .
If the Pro g ra mming C o d e is va lid , a ll me m o ry will b e e ra se d .
Yo u will he a r thre e b e e p s a nd the c o ntro lle r will re turn to
No rm a l Mo d e .
If the Pro g ra mming C o d e is inva lid yo u will he a r a lo ng
b e e p a nd the c o ntro lle r will re turn to No rma l Mo d e witho ut
e ra sing the me m o ry c o nte nts.
?
?
?
?
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Red
Red