C o ntro lle r Func tio na lity
AYC-Fx4 a nd AYC-G x4 fa mily ma nua l Pa g e 42
Auxiliary Mode 2
Auxilia ry input func tio n: To g g le s no rm a l/ se c ure m o d e s
Auxilia ry o utput a c tiva te d by: Aste risk Butto n (*)
E.g . In a uxilia ry m o d e 2, the a uxilia ry re la y c a n func tio n a s a
g e ne ra l purp o se tim e switc h tha t c a n b e a c tiva te d whe n the
Aste risk b utto n (*) is d e p re sse d . The a uxilia ry se tting e sta b lishe s fo r
ho w lo ng the a uxilia ry re la y is to b e a c tiva te d . The a uxilia ry inp ut
c a n switc h the m o d e o f o p e ra tio n o f the c o ntro lle r b e twe e n
no rma l a nd se c ure m o d e . By c o nne c ting a switc h time r o r a la rm
syste m o utp ut to the a uxilia ry inp ut, the c o ntro lle r c a n b e
a uto m a tic a lly switc he d fro m no rma l m o d e (d uring o ffic e ho urs) to
se c ure mo d e (a fte r o ffic e ho urs).
Auxiliary Mode 3
Auxilia ry input func tio n: To g g le s no rm a l/ se c ure m o d e s
Auxilia ry o utput a c tiva te d by: Ala rm s
E.g . In a uxilia ry m o d e 3, the a uxilia ry o utp ut is a c tiva te d if the
c o ntro lle r is ta mp e re d ; tha t is, if the c a se is fo rc ib ly o p e ne d o r
re m o ve d fro m the wa ll. The a uxilia ry inp ut c a n switc h the m o d e o f
o p e ra tio n o f the c o ntro lle r b e twe e n no rma l a nd se c ure mo d e . By
c o nne c ting a switc h tim e r o r a la rm syste m o utp ut to the a uxilia ry
inp ut, the c o ntro lle r c a n b e a uto ma tic a lly switc he d fro m no rm a l
mo d e (d uring o ffic e ho urs) to se c ure m o d e (a fte r o ffic e ho urs).
Auxiliary Mode 4
Auxilia ry input func tio n: To g g le s no rm a l/ se c ure m o d e s
Auxilia ry o utput a c tiva te d by: d ire c t shunt (e xpla na tio n b e lo w)
E.g . In a uxilia ry m o d e 4, the c o ntro lle r is c a p a b le o f b yp a ssing a n
a la rm zo ne b y shunting a n a la rm syste m s d o o r se nso r. The
a uxilia ry o utp ut is to b e wire d in p a ra lle l to the d o o r se nso r o utp ut.
Whe n in use , the a uxilia ry o utp ut is no rm a lly o p e n a nd the d o o r
se nso r func tio ns no rm a lly. Whe n a va lid c o d e is e nte re d , the

Table of Contents