30 AYC-x6355 Installation and User Manual
You hear three beeps.
The system returns to Transmit
mode.
The Programming code cannot be erased, meaning the code 0000
is invalid and does not erase the Programming code.
The factory default 4-digit Programming code is 1234.
7.2.6 Changing the Facility Code
1. Enter Programming mode.
2. Press 4 to enter Menu 4.
The Transmit LED turns red.
3. Enter the new 3-digit code you
wish to set as the Facility code.
You hear three beeps.
The system returns to Transmit
mode.
The Facility code can be in the range of 000 to 255.
The default Facility code is 0.
7.3 Setting the Backlight
1. Enter Programming mode.
2. Press 6 to enter Menu 6.
The Transmit LED turns red.
Mode/Transmit
Door/Program
Red
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Red
Green
Mode/Transmit
Door/Program
Red
Mode/Transmit
Door/Program
Green
Mode/Transmit
Door/Program
Red
Green

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rosslare AYC-H6355 and is the answer not in the manual?

Rosslare AYC-H6355 Specifications

General IconGeneral
BrandRosslare
ModelAYC-H6355
CategoryController
LanguageEnglish

Related product manuals