3.3 Safety mechanisms
See gures 7 ... 12
Safety mechanisms protect both
people and lift. They must not be
disabled!
Post lift danger zones are protected by
safety mechanisms.
Function and condition of the safety mecha-
nisms must be checked daily!
If safety mechanisms are triggered, the post
lift stops immediately.
If the post lift is moved or taken out of use for
long periods, check the safety mechanisms
before re-commissioning and repair if nec-
essary.
If safety mechanisms are defective, the post
lift must be taken out of use immediately
and the main switch locked with a padlock.
Any further use must be prevented until the
machine is fully repaired!
1
Fig. 7
1. Lockable main switch
"ON“ setting: Post lift ready for use.
"OFF“ setting: Post lift out of use. The mains
voltage is still present inside the control box.
Switching off (OFF) immediately stops any
movement of the post lift (= emergency stop).
2. Foot protection arm guard on each lifting arm
When lowering the lift, the arm guard keep the foot
away from the arm (foot protection,otherwise a
crushing or shearing exists).
Always keep the foot and any other objects away
from the lifting arm when lowering the lift.
2
Fig. 8
14