11.11 Installing Gaskets , web cover and
wire chase
These gaskets must be installed to maintain
CE certication.
Route the plastic gaskets around edge of control
cover by 4 turns. Close the cover to base plate on
the column,Push tighten by hand ,then use screw
to attched panel to the back plate.Fig 51.
i
C1
Fig. 33
C
C2
Fig. 51 Detail
Enclosure seal
C1 Long enclosure 1485mm LG,FA7211-24
C2 Short enclosure 127mm LG,FA7211-25
Fig. 51
A
B
C
A
D
D
D
D
D
D
D
D
Wiring Chase
Rib Gasket
53 .giF
Fig. 52 Detail
A Wiring chase attaches into control panel with
(2)
#8 x 1/2" Lg.(B19-#8-1/2")PHTS then snaps
into column.
B 1.26 Meter web cover slides up into extension
then slides down into wire chase (1 Cut-Out).
C 1.13 Meter web cover (3 Cut-Outs)
D Rib Gasket
Start by wire tying all the wires and hoses neatly
and out of the way of the cables. Place edge
and rib gaskets around wire chases. Take
one of the wire chases and attach it to one of
the control panels with two #8- x 1/2" Lg. PHTS. It
may be necessary to remove the cover of the
control assembly to install the wiring chase and
maintain seal position. Snap the front of the
wire chase into the column. Next slide the 1
meter cover up into the column extension and
then down into the wire chase. Repeat for other
column. Adjust covers accordingly to make sure
hoses and wires are covered. Fig. 52.
Fig. 52