3.4 Control unit
All movement of the lift stops immediately
when you release a pressed button.
5
1
3
2
2
3
4
1
Fig. 13
Fig. 14
1. Lockable main switch(For E&M Version)
"ON“ setting: Post lift ready for use.
"OFF“ setting: Post lift out of use. The mains
voltage is still present inside the control box.
Switching off (OFF) immediately stops any
movement of the post lift (= emergency stop).
2. UP button (For E&M Version)
Functions only if the button is pressed,the lift raise.
3. Down button (For E&M Version)
Functions only if the button is pressed,the lift lower.
For M version,it need work together with the
release handle,the lift lower,and if only down button
presssed ,the lift locked on the latch dog.
4. Down button (For E Version)
Functions only if the button is pressed,the lift
locked on the latch dog.keep button pressed until
both carriages lock securely into the latch dog.
5. Safety latch release handle (For M Version)
Functions only if the handle fully down and hold
work together with down button pressed ,the lift
lower.
More detail in next operation section.
16