11.5 Prepare the columns.
Fig. 20 Detail
A Overhead assembly
B See spec drawing
C Overhead mounting bracket
D 3/8“-16NCx3/4“ HHCS and anged lock nut
E Tie bar - use (2) 3/8"-16NCx2-1/2" carria-
ge bolts \ anged lock nuts and spacer(G)
between.
F Use (2) 3/8“-16NCx3/4“ carriage bolts and
flanged lock nuts in front and (2) in back.
Fig.20
Lift Height: See Fig. 20 for overall lift height
of each specic lift model. Add 30mm to
overall height to lowest obstruction.
DO NOT install this lift in a pit or
depression due to re or explosion
risks.
Standard
Height
Setting
102mm
Lower
Height
Setting
216mm
Lowest
Height
Setting
Fig.21 Fig.22
1. Latch Cable Guides for M Series Lifts: Install
the latch cable conduit guide brackets to column
extensions with (1) 1/4”-20NC x 1” HHCS and
1/4”-20NC Flanged Lock Nuts, Fig. 22. HHCS
should go through hole nearest the edge as
shown, Fig. 22.
2. Column Extensions: Install the column extensions
as shown, Fig. 21. Install Tie Bar as shown, Fig.
20.Overhead Mounting Bracket: Install Mounting
Brackets to column extensions, Fig 20.
3. Lift Setting: Position columns in bay using
dimensions shown in spec drawings. With column
lying on the oor, two people can lift the top of the
column and walk towards the base. As the column
approaches vertical, one of the two people should
move to the opposite side of the column and
assist in slowly setting the column at on its base.
Both column base plate backs must be square on
center line of lift. Notches are cut into each base
plate to indicate center line of lift. Using
appropriate equipment, raise carriage to rst latch
E Series Lifts DO NOT Have Latch
Cable Guides or Locking Latch
Cables.
38
B
C
D
E
F
G
Fig. 5
Fig. 4
Fig. 5a