Publication date: Jan., 2009 199
Revision A1
diag
Syntax:
diag
Description:
Diag is used to test whether EEPROM, UART, DRAM and Flash is normal or not.
Argument:
None.
Possible value:
None.
Example:
ES-2410C (diag)# diag
EEPROM Test : OK
UART Test : OK
DRAM Test : OK
Flash Test : OK
Loopback
Syntax:
loopback
Description:
For Internal/External Loopback Test.
Argument:
None.
Possible value:
None.
Example:
ES-2410C(diag)# loopback
Internal Loopback Test : OK
External Loopback Test : Port 2 3 4 6 8 9 10 11 12 13 14 15 16 17 18 19 20
21 22 23 24 25 26 Fail
ES-2410C(diag)#
ping
Syntax:
ping <ip>
Description:
To confirm that whether the remote end-station or switch itself is alive or not.
Argument:
<ip> : IP address or domain name
Possible value:
IP address, e.g. 192.168.2.65 or domain name, e.g. tw.yahoo.com
Example:
ES-2410C(diag)# ping 192.168.2.22
Gateway : 192.168.2.254
192.168.2.22 is alive.