Publication date: Jan, 2009
Revision A1
236
set description
Syntax:
set description <range> <description>
Description:
To set up the flow control function of all ports.
Argument:
<range> syntax: 1,5-7, available from 1 to 26
<description> : set its port description, max 47 characters
Possible value:
<range> : 1 to 26
<description> : set its port description, max 47 characters
Example:
ES-2410C(port)# set description 6 Engineer
ES-2410C(port)# show description
Port Description
------------------:-0D-61-
1
2
3
4 RDTeam
5
6 Engineer
7
8 sales
9
10
11
12
13
……
set flow-control
Syntax:
set flow-control <range> <symmetric | asymmetric>
Description:
To set up the flow control function of all ports.
Argument:
<range>:port range, syntax 1,5-7, available from 1 to 26
<symmetric>: set its flow control as symmetric
<asymmetric>: set its flow control as asymmetric
Possible value:
<range>: 1 to 26
<symmetric | asymmetric>:symmetric or asymmetric
Example:
ES-2410C (port)# set flow-control 3-6 asymmetric