R&D department
2018/08/01
If configuration SMS is incorrect, device will response: setiotime syntax error in DOUTX settings: error text
Where „DOUTX“ is DOUT1 or DOUT2. „Error text“ is described below in the table. It's minimal diagnostic when
something wrong with impulse set in SMS.
Error text Error description
other process controls output Means that other functionality is configured on DOUT's. For example: LED or
buzzer
no comma symbol No comma separator. Comma is used to separate DOUT's configuration
wrong format When was received not enough symbols
wrong level Level can be only logical '1' or '0'. Other values is unacceptable
no space symbol After level symbols must to be space symbol
wrong ms number Wrong time number
wrong repeat number Wrong repeat count number
exceeded max slot For one output is possible to set maximum 10 slot. If this count is exceeded this
error is displayed
pulse is shorter than 10ms Pulse length less than 10 milliseconds was set. It's not acceptable
other reason Includes other reason not described in this table
1.1.23 Banned – temporary banned operators
SMS message is used with 4gen FM device. Purpose is to get information about temporary banned operators.
Answer SMS format: Already banned:X, Newly banned:Y, ops:ZZZ.
Parameter Description
X Number of times when FM tried to ban operator which has
already been in the banned list.
Y Number of times when FM added operator in the banned list.
ZZZ List of currently banned operators (which are still in the list).
Example: pass banned
Response example: Already:1, Newly banned:1, ops:24602,
17