33MOBILE AND WORKSHOP SERIES OPERATION MANUALOctober 2018 | Version: v1-0
5. Conrm the dowel pins are not bent and are aligned
with the mating holes as shown.
TECHNICAL
MASTER DIE MISALIGNMENT TROUBLESHOOTING
6. Ensure the Master dies and dowel pins are in the
correct position. In manual mode, slowly close the
master dies. Note: Special attention is required at
this time, the eight gaps between the main dies need
to be equal, if the gaps are unequal retract (open)
the master dies and reconrm the position of the