Chapter 3: Service & maintenance
Troubleshooting guide 51
3333
Service & maintenance
Radio time DSC logs are
sorted with
wrong time
stamp or
radio time is
incorrect
A wrong radio time indication should occur only if
GPS position source is not connected or providing
correct time data. A valid GPS time signal will
update the UTC time used for time stamping the DSC
logs.
If a GPS/position source is not connected to the VHF
radio and hence position and time is entered
manually, you must enter the "radio time" also
manually, at least after power up. This will ensure
correct time stamping of the DSC logs.
The UTC time is the suggested time to be entered
when prompted for entering position and time
manually (every four hours).
DSC Channel
not free
DSC
transmission
delayed
The transmission of a DSC call which is not of
category distress will be postponed if the VHF radio
is in the process of decoding an incoming DSC call.
As soon as this decoding process has finalized the
transmission will take place.
Handset
configura-
tion
No sound in
earpiece
The earpiece volume may be configured to OFF. See
section Controller setup in the user manual on how
to adjust the earpiece volume of the handset.
Device
failure
If any of the checks and tests described in this
section do not assist in resolving the difficulties
experienced in the operation and/or performance of
the VHF installation, a fault may have developed in
the VHF radio itself.
When contacting an authorized Thrane & Thrane
representative be sure to provide as much
information as possible describing the observed
behavior - also including the type of the VHF radio,
its serial number, and software release version (both
found in the setup menu Controller Setup).
Action Symptom Remedy