8000m Series
- 34 -
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
option when power
on
1: Enabled
F1.12 ~
F1.17
Reserved
F1.18
Wake-up time
delay
0.0~3600s 0.1s 0.0s
F1.19
Restart option after
power-off
0: Disabled
1:Enabled
0
F1.20
Waiting time of
restart after
power-off
0.0~3600s 0.1s 0.0s
F1.21
Over modulation
option
0: Disabled
1:Enabled
0
F2 Group: Motor Parameters
F2.00 Drive model
0:General model (G)
1:Pump model (P)
0
F2.01 Motor rated power 0.4~7.5kW 0.1kW
Different
according
to
inverter
model
F2.02
Motor rated
frequency
10.00Hz~ F0.10 0.01Hz 50.00Hz
F2.03
Motor rated
rotation speed
0~36000rpm 1rpm
Different
according
to
inverter
model
F2.04
Motor rated
voltage
0~480V 1V
F2.05 Motor rated current 0.8~2000A 0.1A