Loading...
8000m Series
- 55 -
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
FD.22
Multi-step speed
10
-100~100% 0.10% 0.00%
FD.23
10
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.24
Multi-step speed
11
-100~100% 0.10% 0.00%
FD.25
11
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.26
Multi-step speed
12
-100~100% 0.10% 0.00%
FD.27
12
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.28
Multi-step speed
13
-100~100% 0.10% 0.00%
FD.29
13
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.30~F
D.33
Reserved
FD.34
Acceleration time
of 0
th
~7
th
steps
0~0xFFFF 0
FD.35
Acceleration time
of 8
th
~15
th
steps
0~0xFFFF 0
FD.36 PLC restart method
0: Restart from 1
st
step
1: Restart from break-off
frequency
0 0
FD.37
PLC operation
time unit
0: second (s) 1: minute (m) 0
FE~FF Group: Reserved Factory Parameters