8000m Series
- 54 -
Function
Code
Function Descriptions
Minimum
Unit
Factory
Setting
Modifica-
tion Type
FD.06 Multi-step speed 2 -100~100% 0.10% 0.00%
FD.07
2
n
d
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.08 Multi-step speed 3 -100~100% 0.10% 0.00%
FD.09
3
r
d
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.10 Multi-step speed 4 -100~100% 0.10% 0.00%
FD.11
4
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.12 Multi-step speed 5 -100~100% 0.10% 0.00%
FD.13
5
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.14 Multi-step speed 6 -100~100% 0.10% 0.00%
FD.15
6
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.16 Multi-step speed 7 -100~100% 0.10% 0.00%
FD.17
7
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.18 Multi-step speed 8 -100~100% 0.10% 0.00%
FD.19
8
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s
FD.20 Multi-step speed 9 -100~100% 0.10% 0.00%
FD.21
9
th
step running
time
0.0~6553s(m) 0.1s(m) 0.0s