VM1000B
- 24 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
curve end segment
F1.10
Stop mode
0:Decelerate to stop
1:Free stopping
0
○
010A
F1.11
Trigging frequency of DC
braking at stop
0.00Hz ~F0.10
0.00Hz
○
010B
F1.12
Waiting time of DC
braking at stop
0.0s ~ 100.0s
0.0s
○
010C
F1.13
The current of DC
braking at
stop
0% ~ 100%
0%
○
010D
F1.14
The time of DC braking at
stop
0.0s ~ 100.0s
0.0s
○
010E
F1.15
Brake use rate
0% ~ 100%
100%
○
010F
F1.16
Zero frequency output
selection
0:Open
1:Closed
1
●
0110
F2 Group: motor parameters
F2.00
Motor type selection
0:Ordinary asynchronous motor
1:Variable frequency asynchronous motor
0
●
0200
F2.01
Motor rated power
0.1kW ~ 400.0kW
Model
dependent
●
0201
F2.02
Motor rated voltage
1V ~ 440V
Model
dependent
●
0202
F2.03
Motor rated current
0.01A ~ 655.35A(<=55kW)
0.1A ~ 6553.5A(>55kW)
Model
dependent
●
0203
F2.04
Motor rated frequency
0.01Hz ~ F0.10
Model
dependent
●
0204
F2.05
Motor rated rotation
speed
1rpm ~ 36000rpm
Model
dependent
●
0205
F2.06
Asynchronous motor
stator resistance
0.001Ω ~ 65.535Ω (<=55kW)
0.0001Ω ~ 6.5535Ω(>55kW)
Model
dependent
●
0206
F2.07
Asynchronous motor
rotator resistance
0.001Ω ~ 65.535Ω (<=55kW)
0.0001Ω ~ 6.5535Ω(>55kW)
Model
dependent
●
0207
F2.08
Asynchronous motor
leakage inductance
0.01Mh ~ 655.35Mh (<=55kW)
0.001Mh ~ 65.535Mh (>55kW)
Model
dependent
●
0208
F2.09
Asynchronous motor
mutual inductance
0.1Mh ~ 6553.5Mh (<=55kW)
0.01Mh ~ 655.35Mh (>55kW)
Model
dependent
●
0209
F2.10
Asynchronous motor
no-
load current
0.01A ~ F2.03 (<=55kW)
0.1A ~ F2.03 (>55kW)
Model
dependent
●
020A
F2.11
Tuning selection
0:No operation
0
●
020B