EasyManua.ls Logo

SAJ VM1000B

SAJ VM1000B
62 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VM1000B
- 34 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
Bit15: PID setting
F7.04
LED display running
parameters 2
0000 FFFF
Bit00: PID feedback
Bit01: PLC stage
Bit02: Feedback speed (0.1Hz)
Bit03: Reserved
Bit04: Remaining running time
Bit05: AI1 voltage before correction
Bit06: AI2 voltage before correction
Bit07: Reserved
Bit08: Linear speed
Bit09: Current power-on time
Bit10: Current running time
Bit11: Reserved
Bit12: Communication setting
Bit13: Reserved
Bit14: Main frequency X diaplay
Bit15: Auxiliary frequency Y display
0
0704
F7.05
LED display stop
parameters
0000 FFFF
Bit00: Setting frequency (Hz)
Bit01: DC bus voltage(V)
Bit02: DI input status
Bit03: DO output status
Bit04: AI1 voltage (V)
Bit05: AI2 voltage (V)
Bit06: Reserved
Bit07: Count value
Bit08: Length value
Bit09: PLC stage
Bit10: Load speed display
Bit11: PID setting
Bit12: Reserved
Bit13: PID feedback value
33
0705
F7.06
Load speed display
coefficient
0.0001 6.5000
0.3
0706
F7.07
Heatsink temperature of
IGBT
0 100
.
0707
F7.08
Heatsink temperature of
rectifier bridge
0 100
.
0708
F7.09
Accumulative running
time
0h 65535h
.
0709
F7.10
Product number
-
.
070A
F7.11
Software version
-
.
070B
F7.12
Number of decimal places
for load speed display
0: 0 decimal places
1: 1 decimal places
2: 2 decimal places
0
070C