VM1000B
- 36 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
F8.18
Startup protection
0: No
1: Protection
0
0812
F8.19
Frequency detection value
(FDT1)
0.00Hz F0.10
50.00Hz
0813
F8.20
Frequency detection
hysteresis (FDT1)
0.0% 100.0%FDT1 level
5.0%
0814
F8.21
Detection range of
frequency reached
0.0% 100.0%maximum frequency
0.00%
0815
F8.22
Jump frequency during
acceleration/deceleration
0: Disabled
1: Enabled
0
0816
F8.23
Accumulated running
time arrive selection
0:Keep running
1:Fault warning
0
0817
F8.24
Accumulated power-on
time arrive action
selection
0:Keep running
1:Fault warning
0
0818
F8.25
Acceleration time 1/2
switching frequency point
0.00Hz F0.10
0.00Hz
0819
F8.26
Deceleration time 1/2
switch frequency point.
0.00Hz F0.10
0.00Hz
081A
F8.27
Terminal JOG preferred
0: Disabled
1: Enabled
1
081B
F8.28
Frequency detection value
(FDT2)
0.00Hz F0.10
50.00Hz
081C
F8.29
Frequency detection
hysteresis (FDT2)
0.0% 100.0%FDT2 level
5.00%
081D
F8.30
Any frequency reaching
detection value 1
0.00Hz F0.10
50.00Hz
081E
F8.31
Any frequency reaching
detection amplitude 1
0.0% 100.0%maximum frequency
0.00%
081F
F8.32
Any frequency reaching
detection value 2
0.00Hz F0.10
50.00Hz
0820
F8.33
Any frequency reaching
detection amplitude 2
0.0% 100.0%maximum frequency
0.00%
0821
F8.34
Zero current detection
level
0.0% 300.0% (motor rated current)
5.00%
0822
F8.35
Zero current detection
delay time
0.01s 600.00s
0.10s
0823
F8.36
Software overcurrent
point
0.0%no detection
0.1% 300.0%(motor rated current
200.00%
0824
F8.37
Software overcurrent
detection delay time
0.00s 600.00s
0.00s
0825