VM1000B
- 41 -
Function
Code
Parameter Name
Setting Range
Default
Property
Address
(HEX)
voltage at instantaneous
power failure
FA.24
Voltage rally judging
time at instantaneous
power failure
0.00s 100.00s
0.50s
0A18
FA.25
Action judging voltage at
instantaneous power
failure
60.0% 100.0%(standard bus voltage)
80.00%
0A19
FA.26
Loss of loads protection
options
0: Disabled
1: Enabled
0
0A1A
FA.27
Loss of loads detection
level
0.0 100.0
10.00%
0A1B
FA.28
Loss of loads detection
time
0.0 60.0s
1.0s
0A1C
FA.29
The decimal point of the
frequency in failure state
1: 1 decimal point
2: 2 decimal point
Single-digit: The third fault frequency
decimal
point
Ten’s digit: The second failure frequency
of the
decimal point
Hundred’s digit: The first failure frequency
of
the decimal point
222
0A1D
FB Group: swing frequency, fixed length and count
FB.00
Swing frequency setting
mode
0: Relative to the central frequency
1: Relative to the maximum frequency
0
0B00
FB.01
Swing frequency
amplitude
0.0% 100.0%
0.00%
0B01
FB.02
Jump frequency
amplitude
0.0% 50.0%
0.00%
0B02
FB.03
Swing frequency cycle
0.1s 3000.0s
10.0s
0B03
FB.04
Triangular wave rising
time coefficient
0.1% 100.0%
50.00%
0B04
FB.05
Setting length
0m 65535m
1000m
0B05
FB.06
Actual length
0m 65535m
0m
0B06
FB.07
Number of pulses per
meter
0.1 6553.5
100
0B07
FB.08
Set count value
1 65535
1000
0B08
FB.09
Designated count value
1 65535
1000
0B09
FC Group: communication parameters
FC.00
Local address
1 2470 is broadcast address
1
0C00