EasyManua.ls Logo

Sako SKI600 - Page 106

Sako SKI600
180 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
100
item AO1 range
Output freq.
(before slip
compensatio)
0V/0mA ~ AO upper limit 0 ~ max. output freq.
2V/4mA ~ AOupper limit 0 ~ max. output freq.
Output freq.
(after slip
compensatio)
0V/0mA ~ AOupper limit 0 ~ max. output freq.
2V/4mA ~ AOupper limit 0 ~ max. output freq.
Set freq.
0V/0mA ~ AOupper limit 0 ~ max. output freq.
2V/4mA ~ AOupper limit 0 ~ max. output freq.
Motor speed
0V/0mA ~ AOupper limit 0 ~ motor synchronous speed
2V/4mA ~ AOupper limit 0 ~ motor synchronous speed
Output current
0V/0mA ~ AOupper limit 0 ~ 2 times of rated current
2V/4mA ~ AOupper limit 0 ~ 2 times of rated current
Output voltage
0V/0mA ~ AOupper limit 0 ~ 1.2 times of rated output voltage
2V/4mA ~ AOupper limit 0 ~ 1.2 times of rated output voltage
Bus voltage
0V/0mA ~ AOupper limit 0 ~ 800V
2V/4mA ~ AOupper limit 0 ~ 800V
PID set value
0V/0mA ~ AOupper limit 0 ~ 100%*10V
2V/4mA ~ AOupper limit 0 ~ 100%*20mA
PID feedback
value
0V/0mA ~ AOupper limit 0 ~ 100%*10V
2V/4mA ~ AOupper limit 0 ~ 100%*20mA
AI1
0V/0mA ~ AOupper limit 0 ~ 10V
2V/4mA ~ AOupper limit 0 ~ 10V
AI2
0V/0mA ~ AOupper limit 0 ~ 20mA
2V/4mA ~ AOupper limit 0 ~ 20mA
Input impulse
frequency
0V/0mA ~ AOupper limit 0 ~ 50KHZ
2V/4mA ~ AOupper limit 0 ~ 50KHZ
Torque current
0V/0mA ~ AOupper limit 0 ~ 2 times of rated current
2V/4mA ~ AOupper limit 0 ~ 2 times of rated current
Flux current
0V/0mA ~ AOupper limit 0 ~ 2 times of rated current
2V/4mA ~ AOupper limit 0 ~ 2 times of rated current
4.2 Detailed Function Description
DO range: DO lower limit ~ DO upper limit, correspond separately to upper limit and lower limit of each
physical quantity.

Table of Contents