100
item AO1 range
Output freq.
(before slip
compensatio)
0V/0mA AO upper limit 0 max. output freq.
2V/4mA AOupper limit 0 max. output freq.
Output freq.
(after slip
compensatio)
0V/0mA AOupper limit 0 max. output freq.
2V/4mA AOupper limit 0 max. output freq.
Set freq.
0V/0mA AOupper limit 0 max. output freq.
2V/4mA AOupper limit 0 max. output freq.
Motor speed
0V/0mA AOupper limit 0 motor synchronous speed
2V/4mA AOupper limit 0 motor synchronous speed
Output current
0V/0mA AOupper limit 0 2 times of rated current
2V/4mA AOupper limit 0 2 times of rated current
Output voltage
0V/0mA AOupper limit 0 1.2 times of rated output voltage
2V/4mA AOupper limit 0 1.2 times of rated output voltage
Bus voltage
0V/0mA AOupper limit 0 800V
2V/4mA AOupper limit 0 800V
PID set value
0V/0mA AOupper limit 0 100%*10V
2V/4mA AOupper limit 0 100%*20mA
PID feedback
value
0V/0mA AOupper limit 0 100%*10V
2V/4mA AOupper limit 0 100%*20mA
AI1
0V/0mA AOupper limit 0 10V
2V/4mA AOupper limit 0 10V
AI2
0V/0mA AOupper limit 0 20mA
2V/4mA AOupper limit 0 20mA
Input impulse
frequency
0V/0mA AOupper limit 0 50KHZ
2V/4mA AOupper limit 0 50KHZ
Torque current
0V/0mA AOupper limit 0 2 times of rated current
2V/4mA AOupper limit 0 2 times of rated current
Flux current
0V/0mA AOupper limit 0 2 times of rated current
2V/4mA AOupper limit 0 2 times of rated current
4.2 Detailed Function Description
DO range: DO lower limit DO upper limit, correspond separately to upper limit and lower limit of each
physical quantity.

Table of Contents

Related product manuals