141
4.2 Detailed Function Description
FF.10
Voltage correction factor
80.0 120.0% 100.0%
FF.12
Selection of temperature detection
methods
0~1 0
FF.14
Second temperature sensor
protection threshold
50.0℃~ 90.0℃ 85.0
FF.11
Current correction factor
50.0 150.0% 100.0%
FF.13
First temperature sensor protection
threshold
50.0℃~ 90.0℃ 85.0
FF.16
Factory Bar Code 1
0 65535 0
FF.18
Manufacture Date(Mon, Day)
0 1231 0
FF.21
Software Upgrade Date (Year)
2010 2100 2018
FF.15
Special information clarity function
0~4 0
FF.17
Factory Bar Code 2
0 65535 0
FF.20
Software Upgrade Date (Mon, Day)
0 1231 0716
FF.09
Software overcurrent point
50.0 250.0% 220.0%
FF.19
Manufacture Date(Year)
2010 2100 2013
FF.22
Special Function Selection
000 111 000
0: prohibit
1: Clear cumulative run time clear monitoring
parameter D-35 content
2: Clear cumulative electrification time clear
monitoring parameter D-36 content
3: Clear cumulative fan run time clear
monitoring parameter D-37 content
4: Clear cumulative electricity consumption
clear monitoring parameter D-38 & D-39
content
Led unit's place: inverter prohibited G /P
model selection
0: invalid
1: e󽗈ective
Led ten's place: current direction selection
0: forward (pointing motor)
1: reverse (pointing inverter)
Led hundred's place: system power choice
0: 5V
1: 3.3V
Led thousand's place: reserved
0: resered
1: resered