028
D Group - Monitoring Parameter Group and Fault Record
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
d-44
Special model monitoring
parameter (reserved)
0
d-45
Special model monitoring
parameter (reserved)
0
d-46
Special model monitoring
parameter (reserved)
0
d-47
Special model monitoring
parameter (reserved)
0
d-48 The third to last fault type 0~30 1 0
d-49
The second to last fault
type
0~30 1 0
d-50 Last fa ult type 0~30 1 0
d-51 Current fault type 0~30 1 0
d-52
Run frequency of current
fault
0.00 ~【F0.16】upper
limit of frequency
0.01Hz 0.00
d-53
Output current of current
fault
0.0 6553.5A 0.1A 0.0
d-54
Busbar voltage of current
fault
0 999V 1V 0
d-55
Input terminal status of
current fault
0 FFH
Note: sequence from
high to low order digit in
binary system
X8/X7/X6/X5/X4/X3/X2/X1
1 0
d-56
Output terminal status of
current fault
0 FH
Note: sequence from
high to low order digit in
binary system R1/Y2/Y1
1 0
d-57 Run state of current fault 0 FFFFH 1 0