031
4.1 Function Code
F0 Group - Basic Run Parameters
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F0.08
Auxiliary
frequency
source B
0: digital set 1 (keypad ▲ / ▼ key,
encoder+F0.12)
1: digital set 2 (terminal UP/DOWN
adjust +F0.13)
2: digital set 3 (communication set)
3: AI1 analog set (0 10V/20mA)
4: AI2 analog set (0 10V)
5: pulse set (0 50KHZ)
6: easy PLC set
7: multistage speed run set
8: PID control set
9: panel potentiometer
1 3
F0.09
Frequency
source
0: main frequency source A
1: A+K*B
2: A-K*B
3: I A-K*B I
4: MAX (A, K*B)
5: MIN (A, K*B)
6: switch from A to K*B (A prior to
K*B)
7: switch from A to (A+K*B) (A prior to
A+K*B)
8: switch from A to (A-K*B)
(A prior to A-K*B)
Note 1: frequency switch needs
Note 2: compared with frequency
source set method, traverse
operation has a higher priority.
1 0