058
4.1 Function Code
F9 Group - MS and PLC Running, Traverse and Fixed Length Control
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modication
F9.00
PLC running
mode
0: stop after single cycle
1: retain value after single cycle
2: continuous cycle of limited times
3: continuous cycle
1 0 ×
F9.01
Input mode of
PLC running
0: auto
1: manually input via dened
multi-function terminal
1 0 ×
F9.02
PLC running
state saving after
power o
0: not save
1: save the stage and frequency
when power o
1 0 ×
F9.03 PLC restart mode
0: restart from the rst stage
1: start from the stage where the
driver stops (fault)
2: start from the stage where the
driver stops(fault) at the recorded
frequency
1 0 ×
F9.04
Limited times of
continuous cycle
1 ~ 65535 1 1 ○
F9.05
Unit of PLC
ru nni n g t i me
0: s 1: m 1 0 ×
F9.06 MS frequency 0
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 5.00 ○
F9.07 MS frequency 1
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 10.00 ○
F9.08 MS frequency 2
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 15.00 ○
F9.09 MS frequency 3
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 20.00 ○
F9.10 MS frequency 4
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 25.00 ○
F9.11 MS frequency 5
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 30.00 ○
F9.12 MS frequency 6
-upper limit Freq. ~ upper limit
Freq.
0.01Hz 40.00 ○