061
4.1 Function Code
F9 Group - MS and PLC Running, Traverse and Fixed Length Control
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
F9.57 Amplitude control
0: 󽗉xed amplitude
1: varied amplitude
1 0 ×
F9.58
Restart method of traverse
mode
0: start to the state
before stop
1: restart without other
requirement
1 0 ×
F9.59
Save traverse state upon
power failure
0: save
1: not save
1 0 ×
F9.60 Preset traverse freq.
0.00Hz upper limit
Freq.
0.01Hz 10.00
F9.61
Preset traverse freq. hold
time
0.0 3600.0s 0.1s 0.0 ×
F9.62 Traverse amplitude 0.0 100.0% 0.1% 0.0%
F9.63 Step freq.
0.0 50.0% (of
amplitude)
0.1% 0.0%
F9.64 Traverse rising time 0.1 3600.0s 0.1s 5.0
F9.65 Traverse falling time 0.1 3600.0s 0.1s 5.0
F9.66 reserved 0
F9.67 Length control 0: disabled 1: enabled 1 0 ×
F9.68 Preset length 0.000 65.535(KM) 0.001KM 0.000
F9.69 Actual length 0.000 65.535(KM) 0.001KM 0.000
F9.70 Length factor 0.100 30.000 0.001 1.000
F9.71 Length calibration 0.001 1.000 0.001 1.000
F9.72 Shaft circumference 0.10 100.00CM 0.01CM 10.00
F9.73 Pulse per revolution (X7) 1 65535 1 1024