071
4.1 Function Code
FE Group - Panel Function Setting and Parameter Management
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modi󽗉cation
FE.00
LCD language option
(only for LCD panel)
0: Chinese
1: English
2: reserved
1 0
FE.01 Key M-FUNC function
0: JOG (jog control)
1: FWD/REV switch
2: clear frequency set by
▲/▼
3: switch between local
operation and remote
control (reserved)
4: reverse
1 0 ×
FE.02 Key STOP/RST function
0: only e󽗈ective to panel
control
1: e󽗈ective to both panel
and terminal control
2: e󽗈ective to both panel
and communication
control
3: e󽗈ective to all control
modes
1 3
FE.03
STOP+RUN emergency
stop
0: disabled
1: coast to stop
1 1
FE.04 Close-Ioop display factor 0.01 100.00 0.01 1.00
FE.05
Display factor of load
rotating speed
0.01 100.00 0.01 1.00
FE.06 Line speed factor 0.01 100.00 0.01 1.00
FE.07
Encoder regulation speed
(served)
1 100 1 70
FE.08
Monitoring parameter
selection 1 in operation
status
0~57 1 0
FE.09
Monitoring parameters
selection 2 in operation
status
0~57 1 5