075
4.1 Function Code
FF Group - Factory Parameter
Function
Code
Name Set Range
Minimum
Unit
Factory
Default
Modication
FF.12
Temperature
Detection Mode
Selection
0: type Ⅰ 1: type Ⅱ 1 0 ◇
FF.13
First Temperature
Sensor Protection
Threshold
50.0℃~ 90.0℃ 0.1℃ 85.0 ◇
FF.14
Second Temperature
Sensor Protection
Threshold
50.0℃~ 90.0℃ 0.1℃ 85.0 ◇
FF.15
Special
information clarity
function
0: forbidden
1: clear cumulative operating time
2: clear cumulative power time
3: clear fan cumulative operation
time
4: clear cumulative power
consumption
1 0 ◇
FF.16 Factory Bar Code 1 0 ~ 65535 1 0 ◇
FF.17 Factory Bar Code 2 0 ~ 65535 1 0 ◇
FF.18
Manufacture
Date(Mon, Day)
0 ~ 1231 1 0 ◇
FF.19
Manufacture
Date(Year)
2010 ~ 2100 1 2013 ◇
FF.20
Software Upgrade
Date (Mon, Day)
0 ~ 1231 1 0716 ◇
FF.21
Software Upgrade
Date (Year)
2010 ~ 2100 1 2018 ◇
FF.22
Special Function
Selection
Led unit's place: inverter
prohibited G /P model selection
0: invalid 1: eective
Led ten's place: current direction
selection
0: forward (pointing motor)
1: re v e r s e ( p o i n t i n g i n v e r te r )
Led hundred's place: system
power choice
0: 5v 1: 3.3v
Led thousand's place: reserved
0: resered 1: resered
1 000 ◇