54 | EN SMARTY v2023.2
Climate
zone
SMARTY
2X V 1.1
SMARTY
2X V 1.1 E
SMARTY
2X V 1.2
SMARTY
2X V 1.2 E
SMARTY
2X V S300
SMARTY
2X V S300 E
Average
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -42,2 -41,2 -38,7 -37,3 -38,7 -37,3
SEC Class A+ A A A A A
AEC [ kWh/a ] 205 203 319 315 319 315
AHS [ kWh/a ] 4668 4559 4596 4454 4596 4454
Cold
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -81,5 -79,4 -77,3 -74,6 -77,3 -74,6
SEC Class A+ A+ A+ A+ A+ A+
AEC [ kWh/a ] 742 740 856 852 856 852
AHS [ kWh/a ] 9131 8918 8991 8713 8991 8713
Warm
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -17,1 -16,7 -13,9 -13,4 -13,9 -13,4
SEC Class E E E E E E
AEC [ kWh/a ] 160 158 274 270 274 270
AHS [ kWh/a ] 2111 2061 2078 2014 2078 2014
Topology Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional
Recovery type Recuperative Recuperative Recuperative Recuperative Recuperative Recuperative
Type of drive (fan) Variable Variable Variable Variable Variable Variable
Thermal eciency [ % ] 88,8 83,5 88,8 83,5 88,8 83,5
Maximum airow [ m
3
/h ] 182 182 182 182 182 182
Fan power at max airow [ W ] 83 83 83 83 83 83
Casing sound power level (Lwa) [ dB(A) ] 52 51 52 51 52 51
Reference airow [ m
3
/s ] 0,035 0,035 0,035 0,035 0,035 0,035
Reference pressure [ Pa ] 50 50 50 50 50 50
SPI [ W/(m
3
/h) ] 0,3 0,3 0,3 0,3 0,3 0,3
Control factor 0,65 0,65 0,85 0,85 0,85 0,85
Declared maximum internal
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Declared maximum external
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Visual lter warning Timer Timer Timer Timer Timer Timer
ErP Compliance 2018 2018 2018 2018 2018 2018
Internet address for disassembly instructions https://select.salda.lt