EN | 57SMARTY v2023.2
Climate
zone
SMARTY
4X P F2 1.1
SMARTY
4X P 1.1 E
SMARTY
4X P F2 1.2
SMARTY
4X P 1.2 E
SMARTY
4X P S300
SMARTY
4X P S300 E
Thermal e󰀩ciency [ % ] 83 70,3 83 70,3 83 70,3
Maximum airow [ m
3
/h ] 573 573 573 573 573 573
Fan power at max airow [ W ] 352 352 352 352 352 352
Casing sound power level (Lwa) [ dB(A) ] 52 52 52 52 52 52
Reference airow [ m
3
/s ] 0,115 0,115 0,115 0,115 0,115 0,115
Reference pressure [ Pa ] 50 50 50 50 50 50
SPI [ W/(m
3
/h) ] 0,34 0,34 0,34 0,34 0,34 0,34
Control factor 0,65 0,65 0,85 0,85 0,85 0,85
Declared maximum internal
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Declared maximum external
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Visual lter warning Timer Timer Timer Timer Timer Timer
ErP Compliance 2018 2018 2018 2018 2018 2018
Internet address for disassembly instructions https://select.salda.lt
Climate
zone
SMARTY
4X V F2 1.1
SMARTY
4X V 1.1 E
SMARTY
4X V F2 1.2
SMARTY
4X V 1.2 E
SMARTY
4X V S300
SMARTY
4X V S300 E
Average
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -40,3 -39,4 -35,9 -34,7 -35,9 -34,7
SEC Class A A A A A A
AEC [ kWh/a ] 234 233 368 366 368 366
AHS [ kWh/a ] 4550 4453 4443 4316 4443 4316
Cold
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -78,5 -76,6 -73 -70,6 -73 -70,6
SEC Class A+ A+ A+ A+ A+ A+
AEC [ kWh/a ] 771 770 905 903 905 903
AHS [ kWh/a ] 8902 8712 8691 8442 8691 8442
Warm
Specic energy con-
sumption (SEC)
[ kWh/m
2
a ] -15,9 -15,5 -12 -11,5 -12 -11,5
SEC Class E E E E E E
AEC [ kWh/a ] 189 188 323 321 323 321
AHS [ kWh/a ] 2058 2014 2009 1951 2009 1951
Topology Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional Bidirectional
Recovery type Recuperative Recuperative Recuperative Recuperative Recuperative Recuperative
Type of drive (fan) Variable Variable Variable Variable Variable Variable
Thermal e󰀩ciency [ % ] 83,1 78,4 83,1 78,4 83,1 78,4
Maximum airow [ m
3
/h ] 560 560 560 560 560 560
Fan power at max airow [ W ] 349 349 349 349 349 349
Casing sound power level (Lwa) [ dB(A) ] 58 58 58 58 58 58
Reference airow [ m
3
/s ] 0,109 0,109 0,109 0,109 0,109 0,109
Reference pressure [ Pa ] 50 50 50 50 50 50
SPI [ W/(m
3
/h) ] 0,36 0,36 0,36 0,36 0,36 0,36
Control factor 0,65 0,65 0,85 0,85 0,85 0,85
Declared maximum internal
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Declared maximum external
leakage rates
[ % ] 1,2 1,2 1,2 1,2 1,2 1,2
Visual lter warning Timer Timer Timer Timer Timer Timer
ErP Compliance 2018 2018 2018 2018 2018 2018
Internet address for disassembly instructions https://select.salda.lt

Table of Contents

Other manuals for Salda Smarty 2X V Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Salda Smarty 2X V Series and is the answer not in the manual?

Salda Smarty 2X V Series Specifications

General IconGeneral
BrandSalda
ModelSmarty 2X V Series
CategoryAir Handlers
LanguageEnglish

Related product manuals