582156110-EN-indC-Pump-20F50 pH.docx 20/11/2020
17
Hoses
Recommendations for hoses.
Keep hoses away from traffic areas, moving parts and
hot areas.
Never subject hoses to temperatures above 60 ° C /
140° F or below 0 ° C / 32° F.
Do not use hoses to pull or move equipment.
Tighten all connections as well as the hoses and
junction fittings before commissioning the equipment.
Check hoses regularly and replace them if damaged.
Never exceed the maximum working pressure stated on
the hose (MWP).
For the assembly of the hoses and the gun: the wearing
of PPE is mandatory.
Tighten to the stop (Hoses + Gun).
Normal stop
To make a normal stop:
Use the air regulator to gradually depressurize the
pump.
Emergency shut-off valve
The stop valve is an emergency stop valve.
This valve must be within easy reach of the operator.