EB 8394 EN 59
Operating the positioner
Positioner that has not been initialized
Touch
or for a long time to move the valve manually.
The valve is only moved in one direction uncontrolled. The bar elements on the display indi-
cate the change in direction.
Touch
to deactivate manual mode.
The Manual mode function can only be exited as described or by interrupting the electrical
supply (cold start). The positioner does not automatically exit this function and return to the
display showing the status indication.
7.11 R
eset
A reset causes an initialization to be undone and all parameters settings are reset to the de-
fault settings (see code list in section11.2).
Enable conguration as described in section7.2.
1. Touch
or until Code P18 appears.
2. Press
and hold for six seconds. 6...5...4...3...2...1 is counted
down on the display.
RST blinks while is pressed. As soon as the key is released, the reset
process is completed and the display returns to status indication (P0).
The fault indication icon is displayed after a reset since the positioner needs to be re-initial-
ized. The error code E2 is also activated (see section9.2).
Note
Note