8 EB 8394 EN
Safety instructions and measures
Servicing explosion-protected devices
If a part of the device on which the explosion protection is based needs to be serviced, the
device must not be put back into operation until a qualied inspector has assessed it accord-
ing to explosion protection requirements, has issued an inspection certicate, or given the
device a mark of conformity. Inspection by a qualied inspector is not required if the manu-
facturer performs a routine test on the device before putting it back into operation. Document
the passing of the routine test by attaching a mark of conformity to the device. Replace ex-
plosion-protected components only with original, routine-tested components by the manufac-
turer.
Devices that have already been operated outside hazardous areas and are intended for fu-
ture use inside hazardous areas must comply with the safety requirements placed on serviced
devices. Before being operated inside hazardous areas, test the devices according to the
specications for servicing explosion-protected devices.
Maintenance, calibration, and work on equipment
Î Only use intrinsically safe current/voltage calibrators and measuring instruments for in-
terconnection with intrinsically safe circuits to check or calibrate the equipment inside or
outside hazardous areas.
Î Observe the maximum permissible values specied in the certicates for intrinsically safe
circuits.
Referenced standards and regulations
Devices with a CE marking fulll the requirements of the Directives 2014/34/EU and
2014/30/EU. The declaration of conformity is included at the end of these instructions.
Referenced documentation
The following documents apply in addition to these mounting and operating instructions:
The mounting and operating instructions of the components on which the positioner is
mounted (valve, actuator, valve accessories, etc.).