EB 8384-2 EN 49
Mounting and start-up
stalled to allow any condensed water
that collects to drain off.
5.3.2 Type3277 Actuator
Î Requiredmountingpartsandaccesso-
ries:Table3onpage24.
Î Observetraveltablesonpage28.
Actuators with 175 to 750 cm² effective ar-
eas (see Fig.7)
Mount the positioner on the yoke. The signal
pressure is routed to the actuator over the
connection block (12), for actuators with fail-
safe action "actuator stem extends" internal-
ly through a hole in the valve yoke and for
"actuator stem retracts" through an external
pipe.
1. Place follower clamp (3) on the actuator
stem, align it and screw tight so that the
mounting screw is located in the groove
of the actuator stem.
2. Mount cover plate (10) with narrow side
ofthecut-out(Fig.7,ontheleft)pointing
towards the signal pressure connection.
Make sure that the gasket (14) points to-
wards the actuator yoke.
3. Foractuatorswith355,700or750cm²,
remove the follower pin (2) on the M le-
ver (1) on the back of the positioner from
pin position 35, reposition it in the hole
for pin position 50 and screw tight.
Foractuators175,240and350cm²
with15mmtravel,keepthefollowerpin
(2) in pin position 35.
4. Insert formed seal (15) into the groove of
the positioner housing.
ExtendsRetracts
2
10 1415
12
31
1
11.1
SUPPLY
13
B
C
1.1
1.2
12
12.1
12
12.2
12.11216
16 16
12.2
SUPPLY
View A
View B
View C
SUPPLYG
G 3/8
A
M lever
Cut-out of
cover plate (10)
Actuator stem extends
Actuator stem retracts
Connection
block (old) with
switch plate (13)
Actuator stem
1 Lever
1.1 Nut
1.2 Disk spring
2 Follower pin
3 Follower clamp
10 Cover plate
11 Cover
11.1 Ventplug
12 Connection block
12.1 Screw
12.2 Stopper or connection for
external piping
13 Switch plate
14 Gasket
15 Formed seal
16 Gasket
Marking
Fig.7: Direct attachment – Signal pressure connection for Type3277 Actuator with 175 to 750cm²